Free Standard Delivery on orders over £75 except for large items. NEXT DAY delivery available for orders placed before 12:00
BROWSE
CART
Shopping Cart
0
COMPARE
WISHLIST

2D LED Bulbs and Bulkheads

New 2D LED 5W 2 Pin GR82D LED 5W 2 Pin GR8

2D LED 5W 2 Pin GR8

£13.54
New 2D LED 5W 4 Pin GR10q2D LED 5W 4 Pin GR10q

2D LED 5W 4 Pin GR10q

£13.54
New 2D LED 7W 2 Pin GR82D LED 7W 2 Pin GR8

2D LED 7W 2 Pin GR8

£33.42
New 2D LED 7W 4 Pin GR10q2D LED 7W 4 Pin GR10q

2D LED 7W 4 Pin GR10q

£33.42
New 2D LED Round DLL 15w 4pin2D LED Round DLL 15w 4pin

2D LED Round DLL 15w 4pin

£12.44
New 2D LED 12W 2 Pin GR82D LED 12W 2 Pin GR8

2D LED 12W 2 Pin GR8

£19.09
New 2D LED 12W 4 Pin GR10q2D LED 12W 4 Pin GR10q

2D LED 12W 4 Pin GR10q

£20.86
SaleNew 2D LED High Output 14W- 4pin2D LED High Output 14W- 4pin

2D LED High Output 14W- 4pin

£32.90  £23.98
Save: 27% off
SaleNew 2D LED Emergency 14W- 4pin2D LED Emergency 14W- 4pin

2D LED Emergency 14W- 4pin

£44.62  £29.98
Save: 33% off
SaleNew 2D LED 4 Pin Emergency D-Shape 16W

2D LED 4 Pin Emergency D-Shape 16W

£63.95  £24.97
Save: 61% off

Replacing a 2D fluorescent lamp or upgrading a bulkhead fitting? Our 2D LED bulbs and bulkheads range includes GR8 2-pin lamps, GR10q 4-pin lamps, emergency options and complete fittings for suitable commercial and communal areas.

A replacement 2D LED lamp, an emergency lamp and a complete LED bulkhead are different products. Choose the type you need first, then match the electrical and physical specifications of the existing installation.

Shop 2D LED lamps by pin type

2-pin GR8 LED bulbs

GR8 2-pin 2D LED bulbs are designed for selected fittings with the corresponding two-pin connection. Check your existing 2D lamp's marking, shape and overall size before selecting a replacement. Our range includes 5W, 7W and 12W options, subject to current stock.

4-pin GR10q LED lamps

For suitable four-pin fittings, compare the 5W 4-pin GR10q 2D LED lamp and other listed outputs. A 4-pin lamp is not interchangeable with a 2-pin fitting. Check whether the product requires the original ballast to be bypassed or removed; this may be essential even if the pins appear to fit.

Emergency 2D LED lamps and bulkheads

Some 2D replacements are designed for emergency lighting or include a sensor. If you are replacing an emergency fitting, verify the battery arrangement, operating mode, emergency duration and compliance requirements for the building before purchase. See our 4-pin emergency 2D LED lamp for product-specific details.

Need the entire fitting rather than just the bulb? Choose a complete 2D LED bulkhead fitting and check the fitting diameter, mounting arrangement, IP rating and whether a lamp is supplied.

Get the replacement right first time

  • Identify GR8 two-pin or GR10q four-pin on the old lamp.
  • Measure lamp diameter, thickness and available space.
  • Compare lumens and colour temperature for the area to be lit.
  • Check ballast, mains wiring, emergency function and sensor requirements.

Many LED 2D replacement lamps need particular control-gear arrangements. Follow the product instructions and use a qualified electrician for any rewiring or testing. This is especially important in emergency lighting and shared buildings.

Replace the lamp or buy a complete bulkhead?

If the existing bulkhead housing is sound and the electrical arrangement is suitable, replacing its 2D fluorescent lamp with a compatible LED model may be a practical option. Start by identifying the old lamp, the control gear inside the fitting and whether the product instructions permit a retrofit. Simply matching the shape and pin count is not enough, particularly where the lamp must be wired directly to the mains after the original ballast is removed.

A complete LED bulkhead fitting may be the better purchase where the old housing is damaged, the diffuser has yellowed or the electrical components are unsuitable. When comparing complete units, look at the external dimensions, mounting positions, IP rating and lumen output. Check whether the fitting is a standard, sensor or emergency model so you do not lose an existing function.

Matching the light output and location

Older 2D lamps were used in stairwells, corridors, communal entrances and utility spaces because they could give broad light from a compact fitting. For a replacement, compare lumens and light colour rather than choosing an LED with the same wattage printed on the old fluorescent lamp. A different wattage may provide similar or better useful light, depending on the actual product.

Think about the surroundings as well. An exposed exterior entrance may need a suitable IP-rated enclosure, while a sheltered indoor hallway may have different priorities. If the existing bulkhead has a sensor, verify the replacement arrangement before ordering a standard lamp or fitting.

Plan emergency lighting replacements carefully

Emergency 2D lighting needs more than a lamp that physically fits. The emergency function must operate with the building's battery and control arrangement, and testing may be required after any change. Check whether the selected product is intended for emergency use and whether a complete fitting replacement is more appropriate. For shared or commercial premises, have a competent electrician review the existing installation and its maintenance obligations.

Buying several units for one building? Record the lamp cap, wattage, fitting dimensions and emergency or sensor status at each location before placing your order. This avoids assuming every bulkhead in the property uses the same components.

Browse our 2D LED lamps, emergency options and bulkheads to match your fitting and order the correct product.

New Products For November - 2D LED Bulbs and Bulkheads

Monthly Specials

Back to Top