{"id":217,"date":"2010-08-16T10:24:05","date_gmt":"2010-08-16T10:24:05","guid":{"rendered":"http:\/\/www.saving-light-bulbs.co.uk\/blog\/?p=217"},"modified":"2016-06-04T16:14:26","modified_gmt":"2016-06-04T15:14:26","slug":"measuring-light-bulb-brightness","status":"publish","type":"post","link":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/measuring-light-bulb-brightness\/","title":{"rendered":"Measuring Light Bulb Brightness"},"content":{"rendered":"<p>When we just had incandescent light bulbs, getting a good indication of\u00a0 the brightness of the bulbs was quite straight forward. People just used to use the light bulb wattage as the brightness measure. So people would say, &#8216;this room needs a 60watt bulb&#8217; or &#8216;this room needs a 100watt bulb&#8217;. Importantly, wattage is not a measurement of light output it is a measurement of power consumption, but as all light bulbs used the same technology this measure proved to be a good brightness indicator. In fact, it almost turned into the universal measure nearly achieving the level of accreditation that a British Standard would!<\/p>\n<p>Now this is all well and good when you only have just one technology, but the plot thickened with the emergence of the fluorescent tube because an 18watt fluorescent tube produced far more light output than a 100 watt incandescent light bulb. Clearly we now need to understand light output in more detail and use more sophisticated light measurement techniques now that we have a spectrum of different <a title=\"light bulb\" href=\" http:\/\/www.saving-light-bulbs.co.uk\/\"><strong>light bulb<\/strong> <\/a> technologies. As an example a 60watt incandescent bulb will produce the same light output as a 15watt CFL but it may only require a 40 watt halogen bulb or a 10watt LED to produce the same light level in a room! The other complexity is the light bulb cover. With traditional bulbs a clear bulb would produce more light than a pearl one and in a similar way, with modern CFL light bulbs a 15watt globe will produce less light output than a 15 watt spiral CFL. This is because the global bulb is manufactured by producing a spiral CFL and then putting a glass global cover on it to give the aesthetic design character. Obviously the cover will absorb some light a and as a consequence the brightness will be reduced.<\/p>\n<p><strong>The Lumens light output measure<\/strong><\/p>\n<p>The simplest and arguably the best standard measurement of light output is the lumens measure. This is a straight forward measurement of the light intensity as perceived by the human eye. This means that it is a very good light output measure as it is adjusted to take into account the different sensitivity the human eye has to different wavelengths. So in summary, the lumens is a measurement of the total light output from a source and generally the base way to compare the light output from from different light bulbs.<\/p>\n<p><strong>Maeasurement of Light Level in a Room<\/strong><\/p>\n<p>Quite often you need to specify a light level within a room which is needed for the purpose that that room is intended for. As an example in an office area or a workshop or indeed in a kitchen the level of light is clearly fundamental, This can be specified by stating the lux value which is a known as the illuminance. Lux is simply a measure of lumens flux on a particular area. So as an example if 500 lumens were concentrated onto an area of 1 square metre then this would correspond to an illuminance level of 500 lux. It is not a straight forward process to convert from lumens to lux as the lux illuminace level will be a function of a whole range of factors, for instance, the geometry of the light bulb, the wall material and\u00a0 the colour of the room. Architectural lighting specialists or lighting suppliers\u00a0 will typically have formulae to provide guidence on what type of light units and lumens output will be needed to provide a lux level within a room.<strong><br \/>\n<\/strong><\/p>\n<p><strong>The Candela<\/strong><\/p>\n<p><img decoding=\"async\" class=\"floatimageright\" src=\"images\/CFL_MR16_11W_160pxhigh.jpg\" alt=\"MR16 CFL Bulb\" \/> Certain types of bulbs like spot lights produce a directional output and certainly with reflector bulbs the intensity of the light will be a function of the angle of the reflector and the corresponding beam. This is where the candela (cd) unit  assists as it is a measure of luminous intensity, which is basically the brightness of the beam in a particular direction. If a light source produces an output of 1 candela uniformly in all directions it will produce 4 \u03a0  , which is approximately 12, lumens output. By example if\u00a0 this was restricted to only produce output across half the area, a hemisphere, but still at 1 candela it would only produce half the lumens output. This means that this measure is particularly useful in measuring the lighting effect produced by light bulbs with reflectors, <a title=\"LED MR16 Bulbs\" href=\" http:\/\/www.saving-light-bulbs.co.uk\/led-ceiling-lights\/gu10\"> LED MR16 Bulbs <\/a> and the\u00a0 <a title=\"halogen spot\" href=\" http:\/\/www.saving-light-bulbs.co.uk\/halogen-bulbs\/spot\/r50-28w-e14\">halogen spot <\/a>. If the angle of the reflector is reduced the light intensity and accordingly the candela (cd) value will increase, but the lumens value would remain the same.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>When we just had incandescent light bulbs, getting a good indication of\u00a0 the brightness of the bulbs was quite straight forward. People just used to use the light bulb wattage as the brightness measure. So people would say, &#8216;this room needs a 60watt bulb&#8217; or &#8216;this room needs a 100watt bulb&#8217;. Importantly, wattage is not &hellip; <a href=\"https:\/\/www.saving-light-bulbs.co.uk\/blog\/measuring-light-bulb-brightness\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">Measuring Light Bulb Brightness<\/span> <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-217","post","type-post","status-publish","format-standard","hentry","category-technologies"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/posts\/217"}],"collection":[{"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/comments?post=217"}],"version-history":[{"count":2,"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/posts\/217\/revisions"}],"predecessor-version":[{"id":1001,"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/posts\/217\/revisions\/1001"}],"wp:attachment":[{"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/media?parent=217"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/categories?post=217"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.saving-light-bulbs.co.uk\/blog\/wp-json\/wp\/v2\/tags?post=217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}